Friday, March 21, 2014

Ambulatory ECG. SYSTEMS AND PROCEDURES

Ambulatory ECG monitoring. Systems and procedures NI Yabluchansky, AV Martynenko, LA Martimyanova

Series: for real doctors. Second edition, corrected, revised.


Kharkov, 2010, 187 p.


The book is dedicated to ambulatory ECG monitoring - from technical aspects to


Examples of clinical application of the proposed draft of the report and


interpretation of the results. Designed for cardiologists, specialists


functional diagnosis, doctors of other specialties related to


use in their work results ambulatory ECG monitoring.


Table of contents


Abbreviations

From the beginnings to the present day

The object of study



  • Sources of electrophysiological processes in the heart

  • Spatio-temporal organization of the myocardium

  • Cardiac conduction system

  • The regulation of the heart



  • Mirror regulation


Systems and procedures



  • Of recorders

  • Maintenance

  • Necessary conditions for a quality check



  • The recording quality

  • Duration of registration

  • Artifacts



  • Cost of research

  • Leads in AECG

  • Statement

  • Protocol



  • Diary

  • Diagnostic and therapeutic procedures

  • Smart AECG



  • The signal-averaged high-resolution AECG


Physiological norms AECG

AECG is much broader long-term ECG

Testing the biological clock



  • On the biological and astronomical clock

  • Basic concepts and indicators of the biological clock



  • Biorhythms

  • The guard at the gate

  • Mechanisms of formation and regulation of biorhythms

  • The most important synchronizer

  • The whole salt in the transient



  • Circadian rhythms and the central clock

  • Dream

  • Wake



  • Aging of the biological clock

  • Circadian index

  • The clinical significance of biorhythms

  • Desynchronoses



  • The value of the biological clock in the AECG


On the quasi-stationary and transient



  • Heart rate variability - a window to the regulatory protsessyorganizma

  • The assessment of the transient



  • By separating the quasi-stationary and transient


HRV technology



  • Methods of HRV

  • Inteprpretatsiya HRV

  • Removing restrictions




Methods of transients



  • Examples of transients with explanations

  • The standard protocol to enter into

  • The main thing in quasi-stationary and transient




AECG and medical smeshatelstva



  • Tale of a lie, but it hints

  • Control regulation

  • Seven times, measure, cut, may not have



  • Extremes are not justified

  • Time to rewrite the scrolls

  • Supra-class drug

  • Dronedarone

  • Dronedarone, or, after all, amiodarone?



  • If you are interested in atrial fibrillation

  • Also arrhythmia

  • Examples of standard reports AECG




The major clinical syndromes and diseases



  • Large adaptation syndrome

  • Arrhythmias

  • A word about heart rate

  • Sinus tachycardia



  • Sinus bradycardia

  • Sinus arrhythmia

  • Sinus block (second degree with a Wenckebach period)



  • Ventricular pre-excitation syndrome

  • Premature complex

  • Paroxysmal tachycardia

  • Atrial rhythm

  • Ventricular rhythms



  • Parasystole

  • Bradyarrhythmias

  • Sinus node dysfunction



  • Violations of the atrioventricular conduction

  • Fibrillation and atrial flutter

  • The risk factor of ventricular tachycardias

  • Brugada syndrome



  • Ventricular late potentials


Literature

************************************************** ************

Labtech Resting and Stress Test ECG solutions








Описание:

Labtech Ltd. is an innovating Hungarian company established in 1990, developing and manufacturing PC-based ambulatory ECG Holter and Resting and Stress Test Systems.
Our company is located in Debrecen, Hungary in central Europe. Debrecen is Hungary's second largest town, situated 220 km east to the capital city, Budapest. Hungary is the member state of the European Union since 1st May 2004. Our address: 4. Vág St. 4031 Debrecen, Hungary.
We maintain a relatively small administrative and sales team and rather focus on development and manufacturing procedures in our company's activity.